Choosing a cladding material is one of the earliest and most consequential decisions on a commercial project. It sets the fire classification route, the structural load, the subframe design, the programme and the long-term maintenance liability. This page covers every material family Dalply supplies, compared across the factors that matter most to a specification decision. Use the links below to jump to a material, or start with the full comparison table.
The panel material is the first decision. Each family has different fire classification, weight, appearance and buildability characteristics.
| Material | Euroclass | Weight (kg/m²) | Typical Formats | Fixing Methods | Key Strength |
|---|---|---|---|---|---|
| Reconstituted Stone (Petrarch) | A2-s1,d0 | 16 to 22 | Up to 1210mm x 3040mm | Secret fix, face fix | 50-year system warranty, stone aesthetic, made in Britain |
| Steni GFRP Composite | B-s1,d0 or A2-s1,d0 (Nature Medium or coarse) | 12 to 19 | Up to 1195mm x 3495mm | Face fix | Printed or coloured finishes, very lightweight, 60 year warranty |
| Timber Composite (Parklex) | B-s1,d0 | 14 to 26 | Up to 1220mm x 2440mm | Secret fix, face fix | Natural timber aesthetic with treated performance |
| Aluminium (ForMe) | A2-s2,d0 | 5 to 12 | 100mm, 150mm, 200mm, 250mm widths, up to 6000mm. Battens: 50mm wide up to 6000mm | Secret fix, face fix, batten-mounted | Lightweight, linear aesthetic, any RAL/NCS colour |
| GRC | A1 | 30 to 60 | Panels up to 1500mm x 3600mm & Bespoke moulded forms | Face fix, anchor fix | Complex profiles, can be mouldable to any form |
| Natural Stone | A1 | 40 to 120+ | Cut to size | Secret fix, mechanical anchor | Authentic material, prestige and heritage projects |
| Composite Stone | A2-s1,d0 | 25 to 50 | Up to 900mm x 3000mm | Secret fix, face fix | Lighter and more consistent than natural stone with anti-graffiti properties |
If your building is over 11m and falls within the relevant purpose groups under Regulation 7(2) of the Building Regulations, your external wall panel must achieve at least A2-s1,d0. That rules out standard Steni (B-s1,d0) and standard Parklex (B-s1,d0) for those elevations.
A2-s1,d0 qualifying systems in the Dalply range: Petrarch (A2 variants), ForMe aluminium (A2-s2,d0), Steni Nature A2 (A2-s1,d0), GRC (A1), natural stone (A1), composite stone (A1 and A2 variants).
Panel weight drives subframe design, bracket loads and, on masonry substrates, the structural assessment of the wall behind. Lightweight systems – ForMe aluminium at 5 to 12 kg/m², Steni at 12 to 19 kg/m², Parklex at 14 to 26 kg/m² – put minimal load on the substrate. Stone-based systems at 40 kg/m² and above require a structural check.
Large-format systems like Petrarch and Steni cover large areas quickly. Smaller modular systems like Petrarch Planx or aluminium SKIN allow more design flexibility but with more pieces to fix. Cut-to-size capability matters on irregular elevations: GRC can be moulded and cut to order, Steni can be factory or site-cut.
Composed of 75% natural stone by-products and recycled fillers, Petrarch significantly reduces the environmental impact of large-scale commercial envelopes without sacrificing the tactile elegance of quarried stone.
Where it wins: stone aesthetic without quarrying variation, complex 3D formed corners and returns, 50-year Downer system warranty. Where to consider an alternative: budget-sensitive projects, or where a lighter structural load is required.
ForMe SKIN panels and Battens 50 are the aluminium products in the Dalply range. Both achieve A2-s2,d0 and come in any RAL or NCS colour. The batten system suits projects where a linear rhythm is part of the architectural language.
Where it wins: buildings where the A2 threshold applies, linear or contemporary aesthetics, lightweight construction, soffit and ceiling applications, any colour requirement.
Parklex Prodema is a high-pressure laminate with a natural timber veneer face bonded to a phenolic core, achieving B-s1,d0. The range includes wall cladding (NATURCLAD), soffit (NATURSOFFIT) and lap siding (NATURSIDING).
Where it wins: natural timber aesthetic with predictable performance, low maintenance compared with untreated timber, soffit and interior-adjacent applications, projects outside the Regulation 7(2) height thresholds.
GRC is Portland cement and fine sand reinforced with alkali-resistant glass fibre. The key property is mouldability: GRC can be formed into complex three-dimensional profiles that flat panel systems cannot produce. GRC is not the same material as fibre cement; the reinforcing fibre is glass rather than cellulose, and the manufacture is entirely different.
Where it wins: bespoke profiles and complex geometry, heritage-adjacent projects, A1 classification. Where to consider an alternative: standard rectangular elevations where mould cost is not justified, programme-critical projects where lead time for bespoke moulding is a constraint.
Natural stone achieves A1 and is specified on prestige commercial projects and where planning, conservation or contextual requirements make it the appropriate choice. At 40 kg/m² and above, a structural assessment of the wall and frame is required.
Where it wins: planning and conservation requirements, prestige elevations, projects where material authenticity is essential. Where to consider an alternative: where programme, weight, cost predictability or consistency matter more than authenticity.
Composite stone panels combine a stone aggregate face with a reinforced core, giving a stone appearance at lower weight and with better consistency than natural stone. Classification is A2-s1,d0 depending on the specific product. It comes with an anti-graffiti coating as standard.
COMPLETE TECHNICAL DATA AND INSTALLATION GUIDES
SEE OUR RAINSCREEN PRODUCTS IN USE IN A RANGE OF PROJECTS
Our rainscreen cladding systems have been specified and supplied on commercial projects across the UK for clients including Balfour Beatty, BAM, Morrison Construction, NORR, Edinburgh Airport and Glasgow Airport.