A2-s1,d0 Fire Rated Cladding Systems

A2-s1,d0 is a Euroclass reaction to fire classification required for cladding panels used on the external walls of relevant buildings under Regulation 7(2) of the Building Regulations. The classification indicates limited combustibility, low smoke production (s1) and no flaming droplets or particles (d0). Dalply supplies A2-s1,d0 rated cladding systems with full certification evidence. Every qualifying system is listed below with the published source for its classification.

Dalply Systems Achieving A2-s1,d0

System Material Euroclass Certification
PetrarchReconstituted Stone Reconstituted Stone A2-s1,d0 BBA certificate, Declaration of Performance
Steni Nature A2 Medium GFRP Composite A2-s1,d0 Declaration of Performance
ForMe SKIN Cladding Panels Aluminium A2-s1,d0 Declaration of Performance
ForMe Battens 50 Aluminium A2-s1,d0 Declaration of Performance
GRC Glass Reinforced Concrete A1 Declaration of Performance
Natural Stone Natural Stone A1 Declaration of Performance
Classification is the panel material classification. Verify against the current published Declaration of Performance for the specific variant and thickness before specification.

What A2-s1,d0 Means

The classification string has three parts. The main class (A2) places the material in the limited combustibility category. The s suffix (s1) describes smoke production, with s1 being the lowest. The d suffix (d0) describes flaming droplets, with d0 meaning none.

Which Buildings Require A2-s1,d0?

Regulation 7(2) of the Building Regulations (England) restricts the use of combustible materials in the external walls of relevant buildings. These include:

  • Buildings with a storey more than 11m above ground level used wholly or partly as a dwelling, institution, other residential purpose, assembly and recreation, or a hospital, school or similar
  • Buildings over 18m meeting the higher-risk building definition under the Building Safety Act 2022 — these also require the Building Safety Regulator’s Gateway 2 process

What A2-s1,d0 Does Not Tell You

A panel classification is a material property, not a system approval. The complete external wall – including insulation, breather membrane, cavity barriers, fixing brackets and subframe – must all be considered. A compliant panel in a non-compliant build-up is not a compliant wall.

  • Insulation must achieve the classification required for the wall type and building height
  • Cavity barriers must be fire-rated and correctly positioned; they do not appear on a panel’s Declaration of Performance
  • Fixings and brackets are part of the external wall and must be addressed in the evidence

The Evidence Pack Building Control Expects

  1. Declaration of Performance for the specific panel variant and thickness.
  2. Classification report or test report reference supporting the Declaration of Performance.
  3. BBA certificate where held, confirming independent assessment of the system.
  4. Evidence of cavity barrier specification and installation methodology.
  5. Fixing and bracket specification, including material classification.
  6. Installation method statement from the contractor.
  7. For higher-risk buildings: documentation meeting the golden thread requirements at Gateway 2.

 

Dalply can supply items 1 to 3 for every system we stock, and can advise on 4 and 5 based on the build-up.

Related Guides and Regulation Content

Certification & Technical Documents

COMPLETE TECHNICAL DATA AND INSTALLATION GUIDES

All certification, Declarations of Performance, BBA certificates, EPDs and installation guides for every system are available in the Technical Hub.

Specification and Project Support

  • Material selection and system shortlisting at RIBA Stage 2 and 3.
  • Specification data for NBS clauses and tender packages.
  • Performance requirements, certification and compliance evidence.
  • Build-up review and detailing support.
  • Supply, lead times and cut-to-size panels.

Rainscreen Cladding Projects

SEE OUR RAINSCREEN PRODUCTS IN USE IN A RANGE OF PROJECTS

Our rainscreen cladding systems have been specified and supplied on commercial projects across the UK for clients including Balfour Beatty, BAM, Morrison Construction, NORR, Edinburgh Airport and Glasgow Airport.