Façade and cladding are not synonyms. A façade is the whole external face of a building – everything visible from outside, including openings, the structural frame where exposed, and any applied finishes. Cladding is the non-load-bearing outer skin that may be applied to it.
There is also a separate set of confusions in the material names: GRC, GFRC, GRP and fibre cement are all different things, and are routinely conflated. This guide sets both straight.
| Term | What it Means | Commonly Confused With |
|---|---|---|
| Façade | The whole external face of a building, including glazing, structure and applied finish. | Cladding - a façade includes the cladding, but cladding is only one element |
| Cladding | The non-load-bearing outer skin applied to the external face. Does not carry structural loads. | External wall - cladding is the outer part of the external wall but not the whole of it |
| External wall | The complete wall construction from internal face to outer surface of the cladding, including substrate, insulation, membranes, subframe and panel. The regulatory definition in Approved Document B (England), the Scottish Technical Handbooks and Welsh Approved Document B includes all these layers. | Cladding - the external wall is the complete construction; cladding is the outermost layer only | Rainscreen | A type of cladding system in which the panel is separated from the thermal and structural envelope by an open, drained and ventilated cavity. | All cladding - not all cladding is rainscreen | Curtain wall | A non-load-bearing external wall system with its own structural metal framework carrying glass and cladding infill panels. | Rainscreen - a rainscreen attaches to a separate structural frame; a curtain wall has its own frame | Building envelope | The complete separation between interior and exterior, including roof, ground floor, external walls and glazing. | Façade - the envelope includes the roof; the façade does not |
External Wall Definition – View Approved Document B, England
External Wall Cladding Definition – View Scottish Technical Handbooks
| Term | What it is | What it is Not | Reinforcing Material | Form |
|---|---|---|---|---|
| GRC | Glass reinforced concrete. Portland cement and fine sand reinforced with alkali-resistant glass fibre. Sprayed or premixed into moulds. | Not fibre cement, not GRP, not GRG | Alkali-resistant glass fibre | Moulded thin-skin panels; any profile |
| GFRC | Glass fibre reinforced concrete. The same material as GRC. Two acronyms from two spellings of glass fibre. | Not a different material from GRC | Alkali-resistant glass fibre | Moulded thin-skin panels; any profile |
| GRP | Glass reinforced plastic (also GFRP). A polymer resin matrix reinforced with glass fibre. | Not GRC or GFRC. Different matrix material. | Glass fibre in a polymer matrix | Panels, moulded forms, structural components | GRG | Glass reinforced gypsum. Used for interior architectural elements only. | Not suitable for external use. Not GRC. | Glass fibre in a gypsum matrix | Interior moulded forms | Fibre cement | Portland cement reinforced with cellulose fibre, formed by the Hatschek process and autoclaved. Flat sheet format. | Not GRC. Different fibre, different matrix, different process, different form. | Cellulose fibre | Flat boards and sheets only | Reconstituted stone | Portland cement and fine aggregate cast into panels. | Not a natural material, not GRC, not cast stone | No fibre (aggregate composite) | Cast panels; flat and 3D forms available | Cast stone | A concrete mix with aggregate and pigment designed to replicate natural stone. Heavier and denser than reconstituted stone. | Not natural stone, not reconstituted stone | No fibre | Cast blocks, copings, architectural features |
A façade is the whole external face of a building. Cladding is the non-loadbearing outer skin applied to it. Cladding is part of the façade, but a façade includes glazing, exposed structure and other elements that are not cladding.
No. GRC is reinforced with alkali-resistant glass fibre and is formed into any moulded profile. Fibre cement is reinforced with cellulose fibre and is formed into flat sheets by the Hatschek process. Different reinforcement, different manufacturing process, different physical form, different applications.
GRC (glass reinforced concrete) has a cement matrix reinforced with glass fibre. GRP (glass reinforced plastic) has a polymer resin matrix reinforced with glass fibre. The matrix material is entirely different, giving different properties, appearance and fire classification. GRC achieves A1. Standard GRP does not.
Glass fibre reinforced concrete – the same material as GRC. Both acronyms refer to Portland cement reinforced with alkali-resistant glass fibre.