The UK does not have a single set of building regulations. England, Scotland and Wales each set their own rules for external wall cladding, and the three frameworks differ in ways that matter to anyone specifying a façade system.
The headline position across all three is the same: buildings above 11m in the relevant purpose groups require external wall cladding materials achieving A2-s1,d0 or A1. The differences lie in how that requirement is framed, when it was introduced, and what routes are available to demonstrate compliance.
The table below gives the position in each jurisdiction. The sections that follow explain each in detail with references to the source documents.
| England | Scotland | Wales | |
|---|---|---|---|
| Primary regulation | Regulation 7(2), Building Regulations 2010 (as amended) | Regulation 8(3), Building (Scotland) Regulations 2004 (as amended by SSI 2022/136) | Regulation 7(2), Building Regulations 2010 as applied in Wales (as amended by Building (Amendment) (Wales) Regulations 2025) |
| Current edition of guidance | Approved Document B, 2019 edition incorporating 2020, 2022, 2025 and 2026 amendments | Building Standards Technical Handbooks - Domestic and Non-Domestic, April 2026 edition | Approved Document B (Wales), as amended December 2025 |
| Classification required (cladding) | A2-s1,d0 or A1 for relevant buildings with a storey above 11m | A2-s1,d0 or A1 for relevant buildings with a storey above 11m | A2-s1,d0 or A1 for relevant buildings with a storey above 11m | Height threshold | Above 11m | At 11m or above | Above 11m (above 18m for some material change of use requirements, reduced to 11m from December 2025) | Metal composite material ban | Yes - relevant buildings and all other buildings | Yes - all buildings, regardless of height | Yes - all buildings, regardless of height (from December 2025) | BS 8414 system test route | Available for England as an alternative where component classifications alone are insufficient | Removed for residential (relevant buildings over 11m) from June 2022 | Available | Key recent change | AD B 2026 amendments in force 30 September 2026 | April 2026 Technical Handbooks in force from 6 April 2026 | Building (Amendment) (Wales) Regulations 2025 in force 20 December 2025 | Source | GOV.UK | gov.scot - building standards | GOV.WALES |
In England, building regulations are made under the Building Act 1984. The Building Regulations 2010 set the functional requirements, and Approved Documents give guidance on how to meet them. Approved Document B covers fire safety.
The combustible materials restriction for external walls sits in Regulation 7(2) of the Building Regulations 2010, as amended. It requires that external wall materials on relevant buildings achieve at least A2-s1,d0 under EN 13501-1.
The 2026 amendments to Approved Document B take effect on 30 September 2026 for building control applications submitted on or after that date. The primary change is consolidation: post-Grenfell external wall guidance that previously sat across separate advice notes and interim documents is now incorporated into the main body of AD B, creating a single authoritative reference.
The classification requirements themselves, A2-s1,d0 or A1 for cladding on relevant buildings above 11m, are not new. They were established by amendments in 2018 and confirmed in 2022. The 2026 edition makes them easier to find and harder to misread.
The 2026 edition also incorporates the second staircase requirement for residential buildings above 18m, which has programme and elevation implications for live schemes.
| Building Type | Height Threshold | Classification Required |
|---|---|---|
| Dwelling, institution, residential care, hospital, school, assembly and recreation | Above 11m (measured to the floor of the highest storey) | A2-s1,d0 or A1 for cladding, insulation and specified attachments |
| Higher-risk buildings (residential, 18m and above) | 18m and above | A2-s1,d0 or A1 - also subject to Building Safety Regulator gateway process |
| Non-residential buildings | No blanket restriction under Regulation 7(2) - unprotected area and boundary distance route available | Varies; consult Approved Document B |
For higher-risk buildings (18m and above), the Building Safety Regulator expects evidence of system performance, not only component classifications. BS 8414 system testing under the Building Research Establishment’s BR 135 criteria remains available as a compliance route, including by way of a documented desktop assessment using tested configurations. For residential buildings above 18m, this route is more tightly scrutinised than for non-residential.
Scotland closed this route for residential buildings above 11m in 2022 – which is a material difference for cross-border specifiers.
In Scotland, building regulations are set under the Building (Scotland) Act 2003. The Building (Scotland) Regulations 2004 set the functional standards, and the Building Standards Technical Handbooks give guidance. There are separate Domestic and Non-Domestic handbooks.
The combustible materials restriction for external walls sits in Regulation 8(3) of the Building (Scotland) Regulations 2004, inserted by the Building (Scotland) Amendment Regulations 2022 (SSI 2022/136), which came into force on 1 June 2022.
Scotland reached the 11m threshold for A2-s1,d0 compliance before England – England applied the same threshold in December 2022. Before 2022, Scotland had already prohibited combustible cladding on high-rise domestic buildings under earlier amendments dating from 2019.
New Technical Handbooks for Scotland came into effect on 6 April 2026, incorporating updates to Section 2 (Fire), Section 3 (Environment) and Section 4 (Safety). Designers seeking to comply with the standards or submit a building warrant application on or after that date should refer to the April 2026 editions.
The Scottish Government also launched a Call for Evidence in January 2026 to review Section 2 (Fire) of the Building Standards, as part of its response to the Grenfell Tower Inquiry’s final report. Outputs from that review may result in further amendments.
Under Regulation 8(6) of the Building (Scotland) Regulations 2004, a relevant building is one having a storey at a height of 11m or more above the ground and which contains a place of assembly, entertainment or recreation; a residential care building or sheltered housing complex; a shared multi-occupancy residential building; a hospital; or a school.
| Building Type | Height Threshold | Classification Required |
|---|---|---|
| Shared multi-occupancy residential, residential care, hospital, school, assembly and entertainment | Storey at 11m or above | A2-s1,d0 or A1 under Regulation 8(3), Building (Scotland) Regulations 2004 |
| Houses (single dwelling) | Storey at 11m or above | A1 or A2 for the external wall of a high-rise domestic building within 1m of a boundary (Handbook clause 2.6.4) |
| All buildings regardless of height | Any height | Metal composite material prohibited under Regulation 8(5) |
Important difference: Scotland removed the BS 8414 system testing route for residential buildings (relevant buildings over 11m) from June 2022. Component classifications alone are required for these buildings; a desktop assessment relying on system tests carried out in different configurations is not an accepted alternative. This is stricter than the England position.
For non-residential relevant buildings in Scotland, the position on system testing routes should be confirmed with the verifier (building standards authority) for the specific project.
Wales uses the Building Regulations 2010 (which apply in both England and Wales) as the legislative base, but the Welsh Government makes its own amendments and issues its own Approved Documents. The Building Regulations in Wales are not the same as in England even though they share the same parent instrument.
The combustible materials restriction sits in Regulations 6(3) and 7(2) of the Building Regulations 2010 as they apply in Wales, most recently amended by the Building (Amendment) (Wales) Regulations 2025, which came into force on 20 December 2025.
The Building (Amendment) (Wales) Regulations 2025 made three significant changes:
A new Approved Document 7 was also issued alongside the amendment regulations, addressing the new metal composite material ban.
| Building Type | Height Threshold | Classification Required |
|---|---|---|
| Dwelling, institution, residential care, hospital, school, assembly and recreation, hostel, hotel, boarding house | Above 11m | A2-s1,d0 or A1 for external wall materials under Regulations 6(3) and 7(2) |
| All buildings | Any height | Relevant metal composite material prohibited (from December 2025) |
| Material change of use | Above 11m (from December 2025, reduced from 18m) | A2-s1,d0 or A1 |
The same product classification, A2-s1,d0 or A1 under EN 13501, satisfies the requirement in all three jurisdictions for relevant buildings above 11m. A cladding system that complies in Scotland also complies in England and Wales for the material classification requirement.
The practical difference is in what evidence is acceptable. For residential buildings in Scotland above 11m, component classifications must be complete and no BS 8414 desktop assessment route is available. In England, the desktop assessment route is still available, though it is more tightly reviewed for higher-risk buildings. In Wales, the position is aligned broadly with England.
Dalply supplies cladding and façade systems with published Declarations of Performance, BBA certificates and technical data for every product in the range. We work on projects across the UK and can confirm which systems meet the classification requirement, advise on the build-up evidence, and support your submission to the relevant building control authority.
No. Approved Document B is guidance for England only. Scotland uses the Building Standards Technical Handbooks, issued by the Scottish Government under the Building (Scotland) Regulations 2004. The April 2026 editions of the Scottish handbooks took effect from 6 April 2026. The requirements for A2-s1,d0 classification on relevant buildings above 11m in Scotland came from the Building (Scotland) Amendment Regulations 2022, which applied from 1 June 2022.
For new buildings, yes in practice: all three require A2-s1,d0 or A1 for relevant buildings with a storey at or above 11m. Wales applied the 11m threshold to material change of use from December 2025, reducing it from the previous 18m trigger. The height measurement method (to the floor of the highest storey) is consistent across all three.
No. Scotland removed the BS 8414 system testing route for residential relevant buildings above 11m when Regulation 8(3) came into force in June 2022. Component classifications must be sufficient on their own. In England, the desktop assessment route is still available but is more closely scrutinised for higher-risk buildings. For non-residential projects in Scotland, confirm the position with the verifier for the specific scheme.
Non-residential buildings in England are covered by Approved Document B but are not subject to the blanket combustible materials restriction that applies to the relevant purpose groups above 11m. Non-residential buildings must still comply with the general fire safety requirements of Part B, and the unprotected area and boundary distance route is available for some buildings. For Scotland and Wales, consult the equivalent guidance for the specific building type.
Schemes where a building control application was submitted before 30 September 2026 may continue to the previous edition of AD B, provided the scheme has also started and is sufficiently progressed. Both conditions must be met. See the companion article on AD B transitional arrangements for the full conditions and how to seek written confirmation.